How to choose measurement
range of sensor
●In static weighting system, sum of constant load and variable load
should not big than 60% of rate load of sensor (rate load of sensor
x number of sensor)
●In dynamic weighting system, it should consider extra affect of
knock
Identification of sensor’s lead wire
and how to connect wire.
● Lead wires of our sensor are usually adopted with four-wick shielded
cable (six-wick shielded able in special use).Red as excitation
positive terminal, yellow as excitation negative terminal, blue
as output positive terminal, white as output negative terminal,
and shielded layer can connect to ground terminal of apparatus
Length of sensor's wire
●If have no special specifications, length of our sense's wire will
according to line of load strength and stress line o sensor is coincident.
This will reduce me affect of incline load and eccentric load to
minimum
| Weighing distance |
< 3t |
3t~8t |
>10t |
| Length of wire |
3m |
5m |
12m |
|